PCRX DC decouplers
Dairyland PCRX DC decouplers for cathodic protection installations.
P.Z.A. CORRSTOP Sp. z o.o. distributes Dairyland Electrical Industries equipment for reducing corrosion risks associated with high-voltage power lines.
What is PCRX?
PCRX is a solid-state device designed to block direct current (DC) while conducting alternating current (AC) to earth. It is used with cathodic protection on metal structures such as pipelines and tanks. Its proven components support reliable, durable operation. Unlike a standard SSD, it incorporates additional electronics that allow interrupted surveys, such as DCVG, without distorting survey results.
How PCRX works
The device decouples DC and conducts AC:
- Under normal conditions, it blocks cathodic protection DC.
- At the same time, it provides a continuous path for AC, including currents induced by power lines.
- When the specified DC voltage threshold is exceeded, it switches to a conducting state to limit voltage.
- Once the disturbance ends, it automatically returns to DC blocking mode.
This switching process can occur repeatedly without degradation of the device's parameters.
Conducting alternating currents to earth
The current flowing in a pipeline wall under the influence of AC voltage induced by a nearby high-voltage line depends on the induced voltage and the resistance of the earthing circuit. Lower combined resistance of the earthing system and decoupler allows greater AC drainage and a greater reduction in induced pipeline voltage.
Main applications
- Protecting pipeline insulating joints.
- Mitigating induced AC voltage on pipelines.
- DC isolation of gradient control mats (GCM).
- Locations where conventional decouplers may interfere with potential measurements, particularly during interrupted surveys.
Key features
- Designed to avoid interference with interrupted cathodic protection surveys.
- Solid-state construction provides a rapid response when the voltage threshold is exceeded.
- Very low DC leakage minimises the effect on cathodic protection.
- Fail-safe operation: the device fails to a short-circuit state.
- No external power supply required.
- Maintenance-free operation with no consumable parts.
- Powder-coated stainless steel enclosure.
- AC fault current and lightning current handling.
PCRX electrical ratings
Standard blocking thresholds are −4.5/+3.5 V or −5.5/+2.5 V, depending on the model. The allowable DC operating range is narrower and depends on the AC component. The continuous AC rating is 45 A RMS. The manufacturer specifies a 100 kA lightning impulse rating (8/20 µs), an operating temperature of −40 to +50 °C and an IP66 enclosure.
| Model | 3 cycles | 10 cycles | 30 cycles |
|---|---|---|---|
| 5 kA | 6800 | 5700 | 5000 |
| 10 kA | 15000 | 12000 | 10000 |
| 15 kA | 27000 | 21000 | 15000 |